Dinstar FXS Manuale Utente

Navigare online o scaricare Manuale Utente per Gateway/Controller Dinstar FXS. Dinstar FXS User manual [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 41
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
DAG Series User Manual V1.0
Dinstar Technologies Co., Ltd.
Address: Floor 6 Guoxing Building Changxing Road Nanshan District Shenzhen China 518057
Telephone: 86-755-26456664
Fax: 86-755-26456659
Email: sales@dinstar.com, support@dinstar.com
Website: www.dinstar.com
Vedere la pagina 0
1 2 3 4 5 6 ... 40 41

Sommario

Pagina 1 - DAG Series User Manual V1.0

DAG Series User Manual V1.0 Dinstar Technologies Co., Ltd. Address: Floor 6 Guoxing Building Changxing Road Nanshan District Shenzhen China 51805

Pagina 2

DAG Series User Manual 7 Dinstar Technologies Co., Ltd. DAG1000(4FXS):195*133*35,DAG1000(4FXO/8FXS/8FXO):240*150*35, DAG2000(16FXS/FXO):440*280*43

Pagina 3 - Table of Contents

DAG Series User Manual 8 Dinstar Technologies Co., Ltd. 2. Basic Operations 2.1 Phone Call 2.1.1 Phone or Extension Numbers 1. Dial the number dir

Pagina 4

DAG Series User Manual 9 Dinstar Technologies Co., Ltd. 2.2 Call Hold Place a call on hold by pressing the “flash” button on the analo

Pagina 5 - 1. Equipment Introduction

DAG Series User Manual 10 Dinstar Technologies Co., Ltd. 2.5 Call Features The DAG serial supports all the traditional and advanced telephony feat

Pagina 6 - 1.2 Equipment Structure

DAG Series User Manual 11 Dinstar Technologies Co., Ltd. 3. Configuration Guide 3.1 Configure LAN Port’s IP Address Connect to the FXS por

Pagina 7

DAG Series User Manual 12 Dinstar Technologies Co., Ltd. 6. Open a web browser, input the default gateway IP address. http://192.168.11.1. You wil

Pagina 8 - 1.3 Connection to DAG serial

DAG Series User Manual 13 Dinstar Technologies Co., Ltd. 3.3 Access DAG serial by Web Browser The web page configuration includes the following:

Pagina 9 - 1.4 Functions and Features

DAG Series User Manual 14 Dinstar Technologies Co., Ltd. 3.3.1 System Information Figure 3-3-2 System Information System information interface sh

Pagina 10 - DAG Series User Manual

DAG Series User Manual 15 Dinstar Technologies Co., Ltd. 2.3.2 Statistics Figure3-3-3 Statistics Statistics option includes three sets of statist

Pagina 11 - 2. Basic Operations

DAG Series User Manual 16 Dinstar Technologies Co., Ltd. 1. Local Network Figure 3-3-5 Local Network Table 3-3-2 Description Local Network Work

Pagina 12 - 2.4 Call Transfer

DAG Series User Manual Dinstar Technologies Co., Ltd. Revision Records File Name DAG Series User Manual Document Version 1.0 Firmware Version

Pagina 13 - 2.5 Call Features

DAG Series User Manual 17 Dinstar Technologies Co., Ltd. LAN Port Config This option specifies the LAN port’s ip address, and its Ethernet network

Pagina 14 - 3. Configuration Guide

DAG Series User Manual 18 Dinstar Technologies Co., Ltd. 2. VLAN Parameter Config Figure 3-3-6 VLAN Parameter Config When a network has a very w

Pagina 15

DAG Series User Manual 19 Dinstar Technologies Co., Ltd. (2)Voice VLAN Voice 802.1Q VLAN ID (0-4095) Fill out an ID to describe a Voice VLAN group

Pagina 16

DAG Series User Manual 20 Dinstar Technologies Co., Ltd. 3.3.4 System Configuration System parameter includes 1) System Config 2) Service Config 3

Pagina 17

DAG Series User Manual 21 Dinstar Technologies Co., Ltd. 2. Service Config In order to adapt to different environments, it is necessary to set so

Pagina 18

DAG Series User Manual 22 Dinstar Technologies Co., Ltd. Table 3-3-4 Service Config RTP start port Defines the local RTP-RTCP port for listening a

Pagina 19

DAG Series User Manual 23 Dinstar Technologies Co., Ltd. 3. SIP Config It is used to set the local SIP port, the SIP server address and port. If

Pagina 20

DAG Series User Manual 24 Dinstar Technologies Co., Ltd. 4. Port Config This page is used to config the account and password of DAG serial, call

Pagina 21

DAG Series User Manual 25 Dinstar Technologies Co., Ltd. 5. Fax Config Figure 3-3-14 Fax Config Table 3-3-7 Fax Config Fax mode T.38 (Auto Detec

Pagina 22

DAG Series User Manual 26 Dinstar Technologies Co., Ltd. 3.3.6 Routing Configuration 1. Routing Parameter Figure 3-3-16 Routing Parameter This op

Pagina 23

DAG Series User Manual Dinstar Technologies Co., Ltd. Table of Contents 1. EQUIPMENT INTRODUCTION ...

Pagina 24 - 2. Service Config

DAG Series User Manual 27 Dinstar Technologies Co., Ltd. 3. Tel in Routing Figure 3-3-19 Tel in Routing Figure 3-3-20 Tel in Routing Add Table

Pagina 25 - Table 3-3-4 Service Config

DAG Series User Manual 28 Dinstar Technologies Co., Ltd. 3.3.7 Manipulation Configuration 1. IP in Destination Numbers Figure 3-3-21 IP in Destin

Pagina 26

DAG Series User Manual 29 Dinstar Technologies Co., Ltd. 2. Tel in Source Numbers Figure 3-3-23 Tel in Source Numbers Figure 3-3-24 Tel in Sourc

Pagina 27

DAG Series User Manual 30 Dinstar Technologies Co., Ltd. 3.3.8 Advanced Configuration 1. Port Group Figure 3-3-26 Port Group Figure 3-3-27 Port

Pagina 28

DAG Series User Manual 31 Dinstar Technologies Co., Ltd. 2. IP Trunk Figure 3-3-28 IP Trunk Add Table 3-3-12 IP Trunk Add Index 64 Priority value

Pagina 29

DAG Series User Manual 32 Dinstar Technologies Co., Ltd. 3.3.9 Management Configuration 1. Firmware Upload Figure 3-3-29 Firmware Upload Table 3-

Pagina 30

DAG Series User Manual 33 Dinstar Technologies Co., Ltd. Table 3-3-14 Syslog Config Enable Syslog Default is No Server Address Storage system log

Pagina 31

DAG Series User Manual 34 Dinstar Technologies Co., Ltd. 7. Login Password Modify login user name and password to avoid unauthorized access to you

Pagina 32

DAG Series User Manual 35 Dinstar Technologies Co., Ltd. 4. FAQ 4.1 How to get the IP address if I have modified the default IP or forgot it ? Cus

Pagina 33

DAG Series User Manual 36 Dinstar Technologies Co., Ltd. 3) If only part of the caller User ID with this problem, please contact the telecom carri

Pagina 34

DAG Series User Manual Dinstar Technologies Co., Ltd. 4.3 Equipment can’t register ...

Pagina 35

DAG Series User Manual 37 Dinstar Technologies Co., Ltd. 5. Glossary ADSL Asymmetric Digital Subscriber Line: Modems attached to twisted pair copp

Pagina 36

DAG Series User Manual 38 Dinstar Technologies Co., Ltd. printer, time and news servers. ECHO CANCELLATION Echo Cancellation is used in telephon

Pagina 37

DAG Series User Manual 2 Dinstar Technologies Co., Ltd. 1. Equipment Introduction 1.1 Introduction The DAG serial is a full feature voice and fa

Pagina 38 - 4.3 Equipment can’t register

DAG Series User Manual 3 Dinstar Technologies Co., Ltd. 1.2 Equipment Structure 1.2.1 Front View Figure 1-2-1 DAG Series Front View Table 1-2-1 D

Pagina 39

DAG Series User Manual 4 Dinstar Technologies Co., Ltd. 1.2.2 Rear View Figure 1-2-2 DAG Series Rear View Table 1-2 -2 Description of DAG Series

Pagina 40 - 5. Glossary

DAG Series User Manual 5 Dinstar Technologies Co., Ltd. 1.3 Connection to DAG serial The DAG serial is easy to configure using the embedded GUI pa

Pagina 41

DAG Series User Manual 6 Dinstar Technologies Co., Ltd. 1.4 Functions and Features 1.4.1 Protocol standard supported ● Standard SIP /MGCP protoco

Commenti su questo manuale

Nessun commento